Lenovo THINKSERVER RS210 User Manual

Page 44

Advertising
background image

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.

v

See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

A Uncorrectable Bus Error has
occurred on system %1.
(%1 = CIM_ComputerSystem.
ElementName)

Error

A bus uncorrectable error
has occurred.
(Sensor = Critical Int CPU)

1.

Check the system-event log.

2.

Check the microprocessor
error LEDs.

3.

(Trained service technician
only) Replace microprocessor
.

4.

Check for a server firmware
update.
Important:

Some cluster

solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

5.

(Trained service technician
only) Replace the system
board.

A Uncorrectable Bus Error has
occurred on system %1.
(%1 = CIM_ComputerSystem.
ElementName)

Error

A bus uncorrectable error
has occurred.
(Sensor = Critical Int DIM)

1.

Check the system-event log.

2.

Check the DIMM error LEDs.

3.

Remove the failing DIMM
from the system board.

4.

Check for a server firmware
update.
Important:

Some cluster

solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

5.

Make sure that the installed
DIMMs are supported and
configured correctly.

6.

(Trained service technician
only) Replace the system
board.

36

ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual