Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.

v

See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

The Processor CPU nStatus has
Failed with IERR.
(n = microprocessor number)

Error

A processor failed - IERR
condition has occurred.

1.

Make sure that the latest
levels of firmware and device
drivers are installed for all
adapters and standard
devices, such as Ethernet,
SCSI, and SAS.
Important:

Some cluster

solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.

2.

Run the DSA program for the
hard disk drives and other
I/O devices.

3.

(Trained service technician
only) Replace microprocessor
n.

(n = microprocessor number)

An Over-Temperature Condition has
been detected on the Processor CPU
nStatus.
(n = microprocessor number)

Error

An overtemperature
condition has occurred for
microprocessor n.
(n = microprocessor number)

1.

Make sure that the fans are
operating, that there are no
obstructions to the airflow,
that the air baffle is in place
and correctly installed, and
that the server cover is
installed and completely
closed.

2.

Make sure that the heat sink
for microprocessor n is
installed correctly.

3.

(Trained service technician
only) Replace microprocessor
n.

(n = microprocessor number)