Running the diagnostic programs, Diagnostic text messages, Viewing the test log – Lenovo THINKSERVER RS210 User Manual

Page 77

Advertising
background image

Utilities are available to reset and update the diagnostics code on the integrated USB flash device, if the
diagnostic partition becomes damaged and does not start the diagnostic programs. For more information
and to download the utilities, go to http://www.lenovo.com/support.

Running the diagnostic programs

To run the diagnostic programs, complete the following steps:
1.

If the server is running, turn off the server and all attached devices.

2.

Turn on all attached devices; then, turn on the server.

3.

When the prompt <F2> Diagnostics is displayed, press F2.

Note:

The DSA Preboot diagnostic program might appear to be unresponsive for an unusual length of

time when you start the program. This is normal operation while the program loads.

4.

Optionally, select Quit to DSA to exit from the stand-alone memory diagnostic program.

Note:

After you exit from the stand-alone memory diagnostic environment, you must restart the

server to access the stand-alone memory diagnostic environment again.

5.

Select gui to display the graphical user interface, or select cmd to display the DSA interactive menu.

6.

Follow the instructions on the screen to select the diagnostic test to run.

If the diagnostic programs do not detect any hardware errors but the problem remains during normal
server operation, a software error might be the cause. If you suspect a software problem, see the
information that comes with your software.

A single problem might cause more than one error message. When this happens, correct the cause of the
first error message. The other error messages usually will not occur the next time you run the diagnostic
programs.

Exception:

If multiple error codes or system-board LEDs indicate a microprocessor error, the error might

be in a microprocessor or in a microprocessor socket. See “Microprocessor problems” on page 58 for
information about diagnosing microprocessor problems.

If the server stops during testing and you cannot continue, restart the server and try running the
diagnostic programs again. If the problem remains, replace the component that was being tested when
the server stopped.

Diagnostic text messages

Diagnostic text messages are displayed while the tests are running. A diagnostic text message contains
one of the following results:

Passed:

The test was completed without any errors.

Failed:

The test detected an error.

Aborted:

The test could not proceed because of the server configuration

Additional information concerning test failures is available in the extended diagnostic results for each
test.

Viewing the test log

To view the test log when the tests are completed, type the view command in the DSA interactive menu,
or select Diagnostic Event Log in the graphical user interface. To transfer DSA Preboot collections to an
external USB device, type the copy command in the DSA interactive menu.