Figure 2-2, Positioning the chassis in the rack -5 – Nortel Networks 450 User Manual

Page 113

Advertising
background image

Installing the BayStack 450 Switch

302401-D Rev 00

2-5

The BayStack 450 switch occupies a 1.6-unit (1.6u) rack space and can be
installed in most standard 19-inch racks. The rack must be grounded to the same
grounding electrode used by the power service in the area. The ground path must
be permanent and must not exceed 1 ohm of resistance from the rack to the
grounding electrode.

To install the BayStack 450 switch in a rack, follow these steps:

1.

Determine how far you want the switch to protrude in front of the rack.

Figure 2-2.

Positioning the Chassis in the Rack