BayStack 450 10/100/1000 Series Switches

302401-D Rev 00

1-61

The MultiLink Trunk Configuration screen opens (

Figure 1-42

).

Figure 1-42.

MultiLink Trunk Configuration Screen for Switch S1

Switch S1 is configured as follows:

Trunk (read only) indicates the trunks (1 to 6) that correspond to the switch
ports specified in the Trunk Members fields.

Trunk Members (Unit/Port) indicates the ports that can be configured, in
each row, to create the corresponding trunk:

Ports 15, 17, 19, and 21 are assigned as trunk members of trunk 1.

Ports 25 and 26 are assigned as trunk members of trunk 2.

Note:

The Unit value (in the Unit/Port field) is not configurable when the

switch is operating standalone. For detailed information about the MultiLink
Trunk Configuration screen fields, see “MultiLink Trunk Configuration” on
page 3-37.

MultiLink Trunk Configuration

Trunk Trunk Members (Unit/Port) STP Learning Trunk Mode Trunk Status
----- ------------------------------- ------------ --------------- ------------
1 [ /15 ][ /17 ][ /19 ][ /21 ] [ Normal ] Basic [ Enabled ]
2 [ /25 ][ /26 ][ / ][ / ] [ Normal ] Basic [ Enabled ]
3 [ /2 ][ /4 ][ / ][ / ] [ Normal ] Basic [ Enabled ]
4 [ /14 ][ /16 ][ / ][ / ] [ Normal ] Basic [ Enabled ]
5 [ /22 ][ /24 ][ / ][ / ] [ Fast ] Basic [ Enabled ]
6 [ / ][ / ][ / ][ / ] [ Normal ] Basic [ Disabled ]

Trunk Trunk Name
----- ------------------
1 [ S1:T1 to FS2 ]
2 [ S1:T2 to S2 ]
3 [ S1:T3 to S2 ]
4 [ S1:T4 to S3 ]
5 [ S1:T5 to S4 ]
6 [ Trunk #6 ]

Enter text, press <Return> or <Enter> when complete.
Press Ctrl-R to return to previous menu. Press Ctrl-C to return to Main Menu.