Table 3-4, System characteristics screen fields -16 – Nortel Networks 450 User Manual

Page 148

Advertising
background image

Using the BayStack 450 10/100/1000 Series Switch

3-16

302401-D Rev 00

Table 3-4.

System Characteristics Screen Fields

Field

Description

Operation Mode

Read-only field that indicates the operation mode of the unit, for example:

When the unit is part of a stack configuration, the (read-only) field indicates the
unit is operational in a stack, and lists the current unit number of this switch. In
this example (see

Figure 3-5

on

page 3-15

), the current unit number is Unit 2.

When the unit is

not part of a stack configuration (operating standalone), the

read-only field indicates the unit is operating as a switch. When in this operation
mode, the Size of Stack and Base Unit fields (see following description) do not
appear.

Size of Stack

This read-only field only appears when the switch is participating in a stack
configuration. This field indicates the number of units configured in the stack
configuration (1 to 8 units maximum).

Base Unit

This read-only field only appears when the switch is participating in a stack
configuration. This field indicates the unit number of the switch that is currently
operating as the base unit.

MAC Address

The MAC address of the BayStack 450 switch or, when the switch is participating in a
stack configuration, the MAC address of the stack configuration.

Reset Count

A read-only field that indicates the number of resets since the operational firmware
was first loaded on the switch.

Default Value

1

Range

0 to 2

32

-1

Last Reset Type

A read-only field that indicates the last type of reset.

Default Value

Power Cycle

Range

Power Cycle, Software Download, Management Reset,
Management Factory Reset

Power Status

A read-only field that indicates the current power source (primary, RPSU, or both).

Default Value

Primary Power

Range

Primary Power, Redundant Power, Primary and Redundant Power

Local MDA Type

A read-only field that indicates the MDA type that is configured in this unit.

sysDescr

A read-only field that specifies the hardware and software version.

(continued)

kombk.book Page 16 Tuesday, June 29, 1999 3:25 PM

Advertising