Table 3-17, Port mirroring configuration screen fields -46 – Nortel Networks 450 User Manual

Page 178

Advertising
background image

Using the BayStack 450 10/100/1000 Series Switch

3-46

302401-D Rev 00

Table 3-17

describes the

Port Mirroring Configuration screen fields.

Table 3-17.

Port Mirroring Configuration Screen Fields

Field

Description

Monitoring Mode

Allows a user to select any one of six port-based monitoring modes or any one of five
address-based monitoring modes (see

Table 3-18

). Selecting any one of the six

port-based modes activates the port X and port Y screen fields, where a user can
choose up to two ports to monitor. Selecting any one of the five

address-based

modes activates the Address A and Address B screen fields, where a user can
specify MAC addresses to monitor.

Default Value

Disabled

Range

See

Table 3-18

Monitor Unit/Port

Indicates the port number (of the specified unit) that is designated as the monitor
port.

Default Value

Zero-length string

Range

1 to 8/ 1 to 28 (depending on model type)

Unit/Port X

Indicates one of the ports (of the specified unit) that will be monitored by the
designated port monitor when one of the port-based monitoring modes is selected.
This port will be monitored according to the value of Port X in the Monitoring Mode
field (see

Table 3-18

).

Default Value

Zero-length string

Range

1 to 8/ 1 to 28 (depending on model type)

Unit/Port Y

Indicates one of the ports (of the specified unit) that will be monitored by the
designated port monitor when one of the port-based monitoring modes is selected.
When installed as a standalone switch, the screen does not display the (Unit/) field
designation. This port will be monitored according to the value of Port Y in the
Monitoring Mode field (see

Table 3-18

).

Default Value

Zero-length string

Range

1 to 8/ 1 to 28 (depending on model type)

Address A

Indicates the MAC addresses that will be monitored by the designated port monitor
when one of the address-based monitoring modes is selected. This port will be
monitored according to the value of Address A in the selected Monitoring Mode field
(see

Table 3-18

). Users can enter the MAC address from this screen or from the MAC

Address Table screen. The entry is displayed and can be modified by either screen
(see “

MAC Address Table

” on

page 3-20

).

Default Value

00-00-00-00-00-00 (no MAC address assigned)

Range

00-00-00-00-00-00 to FF-FF-FF-FF-FF-FF

(continued)

kombk.book Page 46 Tuesday, June 29, 1999 3:25 PM