Table 3-17, Port mirroring configuration screen fields -46 – Nortel Networks 450 User Manual

Page 178

Advertising
background image

Using the BayStack 450 10/100/1000 Series Switch

3-46

302401-D Rev 00

Table 3-17

describes the

Port Mirroring Configuration screen fields.

Table 3-17.

Port Mirroring Configuration Screen Fields

Field

Description

Monitoring Mode

Allows a user to select any one of six port-based monitoring modes or any one of five
address-based monitoring modes (see

Table 3-18

). Selecting any one of the six

port-based modes activates the port X and port Y screen fields, where a user can
choose up to two ports to monitor. Selecting any one of the five

address-based

modes activates the Address A and Address B screen fields, where a user can
specify MAC addresses to monitor.

Default Value

Disabled

Range

See

Table 3-18

Monitor Unit/Port

Indicates the port number (of the specified unit) that is designated as the monitor
port.

Default Value

Zero-length string

Range

1 to 8/ 1 to 28 (depending on model type)

Unit/Port X

Indicates one of the ports (of the specified unit) that will be monitored by the
designated port monitor when one of the port-based monitoring modes is selected.
This port will be monitored according to the value of Port X in the Monitoring Mode
field (see

Table 3-18

).

Default Value

Zero-length string

Range

1 to 8/ 1 to 28 (depending on model type)

Unit/Port Y

Indicates one of the ports (of the specified unit) that will be monitored by the
designated port monitor when one of the port-based monitoring modes is selected.
When installed as a standalone switch, the screen does not display the (Unit/) field
designation. This port will be monitored according to the value of Port Y in the
Monitoring Mode field (see

Table 3-18

).

Default Value

Zero-length string

Range

1 to 8/ 1 to 28 (depending on model type)

Address A

Indicates the MAC addresses that will be monitored by the designated port monitor
when one of the address-based monitoring modes is selected. This port will be
monitored according to the value of Address A in the selected Monitoring Mode field
(see

Table 3-18

). Users can enter the MAC address from this screen or from the MAC

Address Table screen. The entry is displayed and can be modified by either screen
(see

MAC Address Table

” on

page 3-20

).

Default Value

00-00-00-00-00-00 (no MAC address assigned)

Range

00-00-00-00-00-00 to FF-FF-FF-FF-FF-FF

(continued)

kombk.book Page 46 Tuesday, June 29, 1999 3:25 PM

Advertising