Replacing an mda with a different model, Figure c-5 – Nortel Networks 450 User Manual

Page 258

Advertising
background image

Using the BayStack 450 10/100/1000 Series Switch

C-12

302401-D Rev 00

3.

Insert the MDA into the Uplink Module card guides (

Figure C-5

).

Make sure the MDA slides in on the card guides. Failure to align the MDA to
the card guides could damage the pins.

Figure C-5.

Installing an MDA

4.

Press the MDA firmly into the Uplink Module slot.

Be sure that the MDA is fully seated into the mating connector.

5.

Secure the MDA by tightening the thumb screws on the MDA front panel.

6.

Attach devices to the MDA ports.

After connecting the port cables, continue to follow the instructions in that manual
to connect power and verify the installation.

Replacing an MDA with a Different Model

When replacing an installed MDA with another type of MDA, complete the
following steps to clear the switch NVRAM:

Note:

If you are replacing an installed MDA with another type of MDA, see

“Replacing an MDA with a Different Model

” on

C-13

.

Note:

The IEEE 802.3u specification requires that all ports operating at 100

Mb/s use only Category 5 unshielded twisted pair (UTP) cabling.

BS35046A