Figure 1-37. setting port priority example -56 – Nortel Networks 450 User Manual

Page 82

Advertising
background image

Using the BayStack 450 10/100/1000 Series Switch

1-56

302401-D Rev 00

5.

Select a priority level from the range shown in the Traffic Class
Configuration screen (or modify the Traffic Class parameters to suit your
needs).

6.

Assign the priority level to ports using the VLAN Port Configuration
screen:

a.

Press [Ctrl]-R to return to the VLAN Configuration Menu.

b.

From the VLAN Configuration Menu, select VLAN Port
Configuration (or press c).

The VLAN Port Configuration screen opens (

Figure 1-37

).

Figure 1-37

shows the VLAN Port Configuration screen setup for port 4 in

Figure 1-34

on

page 1-53

.

Figure 1-37.

Setting Port Priority Example

For more information about using this feature, see “VLAN Configuration Menu”
on page 3-22.

VLAN Port Configuration

Port: [ 4 ]
Filter Tagged Frames: [ No ]
Filter Untagged Frames: [ No ]
Filter Unregistered Frames: [ No ]
Port Name: [ Principal's port ]
PVID: [ 2 ]
Port Priority: [ 6 ]

Enter text, press <Return> or <Enter> when complete.
Press Ctrl-R to return to previous menu. Press Ctrl-C to return to Main Menu.

kombk.book Page 56 Tuesday, June 29, 1999 3:25 PM