Using the Console Interface

302401-D Rev 00

3-79

You can monitor the software download process by observing the BayStack 450
switch LEDs (see

“LED Indications During the Download Process

” on

page 3-80

).

Figure 3-33.

Software Download Screen

Table 3-28

describes the Software Download screen fields.

Table 3-28.

Software Download Screen Fields

Field

Description

Image Filename The software image load file name.

Note:

Certain software releases may require you to download two images: the

boot

code image and the agent image. For proper operation of the switch, the new boot code
image must be downloaded

before the agent image is downloaded.

Default Value

Zero-length string

Range

An ASCII string of up to 30 printable characters

(continued)

Software Download

Image Filename: [ b4501102.img ]
TFTP Server IP Address: [ 192.0.1.12 ]

Start TFTP Load of New Image: [ Yes ]

The Software Download process has started. Do NOT power down the
switch before the process has completed (approximately 10 minutes).

Enter text, press <Return> or <Enter> to select choice.
Press Ctrl-R to return to previous menu. Press Ctrl-C to return to Main Menu.