Vlan port configuration, Vlan port configuration -26 – Nortel Networks 450 User Manual

Page 158

Advertising
background image

Using the BayStack 450 10/100/1000 Series Switch

3-26

302401-D Rev 00

VLAN Port Configuration

The VLAN Port Configuration screen (

Figure 3-10

) allows you to configure

specified switch ports with the appropriate PVID/VLAN association that enables
the creation of broadcast domains (see

“Shared Servers

” on

page 1-40

for more

information about setting up broadcast domains).

You can configure specified switch ports to filter (discard) all received tagged
frames, untagged frames, or unregistered frames (see

“IEEE 802.1Q Tagging

” on

page 1-33

).

You can also prioritize the order in which the switch forwards packets, on a
per-port basis (see

“IEEE 802.1p Prioritizing

on

page 1-53

).

Choose VLAN Port Configuration (or press c) from the VLAN Configuration
Menu screen to open the VLAN Port Configuration screen.

The Port Membership fields are displayed in six-port groups (for example, 1-6, 7-12,
13-18). The number of ports displayed depends on the switch model or type of
optional MDA installed in the Uplink Module slot.

Default

U (All ports are assigned as untagged members of VLAN 1.)

Range

U, T, and -

Table 3-8.

VLAN Configuration Screen Fields

(continued)

Field

Description

kombk.book Page 26 Tuesday, June 29, 1999 3:25 PM

Advertising