Figure 1-25.

VLAN Broadcast Domains Within the Switch

For example, to create a broadcast domain for each VLAN shown in

Figure 1-25

,

configure each VLAN with a port membership, and each port with the appropriate
PVID/VLAN association:

Ports 8, 6, and 11 are untagged members of VLAN 1.

The PVID/VLAN association for ports 6 and 11 is: PVID = 1.

Ports 2, 4, 10, and 8 are untagged members of VLAN 2.

The PVID/VLAN association for ports 2, 4, and 10 is: PVID = 2.

Ports 2, 4, 10, 8, 6, and 11 are untagged members of VLAN 3.

The PVID/VLAN association for port 8 is: PVID = 3.

The following steps show how to use the VLAN configuration screens to
configure the VLAN 3 broadcast domain shown in

Figure 1-25

.

Port 2

BS45019A

Port 4

Port 10

Port 8

VLAN 3

V2

V2

V2

V1

V2

VLAN 2

VLAN 1

S1

Key

VLAN 1 (PVID = 1)
VLAN 2 (PVID = 2)
VLAN 3 (PVID = 3)

PVID = 2

PVID = 3

V3

PVID = 1

Port 11

Port 6

kombk.book Page 41 Tuesday, June 29, 1999 3:25 PM