Worst-case power budget and penalties, Table b-8 – Nortel Networks 450 User Manual

Page 246

Advertising
background image

Using the BayStack 450 10/100/1000 Series Switch

B-6

302401-D Rev 00

Worst-Case Power Budget and Penalties

Table B-8

lists the worst-case power budget and penalties for the 1000BASE-LX

models:

Receive sensitivity

– 19

dBm

Return loss (minimum)

12

dB

Stressed receive sensitivity

1

,

2

– 14.4

dBm

Receive electrical 3 dB upper cutoff frequency (maximum)

1500

MHz

Vertical eye-closure penalty

3

2.60

dB

1

Measured with conformance test signal at TP3 (see IEEE 802.3, Clause 38.6.11) for BER = 10

–12

at the eye center.

2

Measured with a transmit signal having a 9 dB extinction ratio. If another extinction ratio is used, the stressed receive

sensitivity should be corrected for the extinction ratio penalty.

3

Vertical eye-closure penalty is a test condition for measuring stressed receive sensitivity. It is not a required

characteristic of the receiver.

Note:

The link power penalties (

Table B-8

) are used for link power budget

calculations only. They are not requirements and are not meant to be tested.

Table B-8.

Worst-Case 1000BASE-LX Power Budget and Penalties

Parameter

62.5 um MMF

50 um MMF

10 um SMF

Unit

Modal bandwidth as measured at
1300 nm (minimum, overfilled launch)

500

400

500

N/A

MHz · km

Link power budget

7.5

7.5

7.5

8.0

dB

Operating

distance 550

550

550

5000

m

Channel insertion loss

2.35

2.35

2.35

4.57

dB

Link power penalties

3.48

5.08

3.96

3.27

dB

Unallocated margin in link power budget

1.67

0.07

1.19

0.16

dB

Table B-7.

1000BASE-LX Receive Characteristics

(continued)

Description Value

Units