MCS 4-server Sun Fire V100 Solaris Installation and Commissioning Guide

161

Copyright © 2006 Nortel Networks

9

Enter the secondary machine physical IP address for the dmfe1
interface:
<Physical IP address of the dmfe1 interface of
the physical server you are installing> [Enter]

Example: 192.168.14.13

10

Enter the <machine logical IP addresses of the
servers>

that are the ping targets.

Note: Do not enter the IP address of the server you are
working on.

You will see the following message:

IP Multipathing needs a set of reliable hosts to
ping against. Select a set of three IP addresses
in this subnet that belong to reliable nodes
(such as fault tolerant servers). Select the
three nodes from the following list, in order of
preference:

For IPMP GROUPS:

— Machine Logical IP address of the two database servers

— Machine Logical IP address of the Management server

— Machine Logical IP address of the CAM server

— Other optional devices (PRI Gateway host)

— Router (this one is already selected by default route)

Provide between two and six ping targets or each IPMP group
for proper IPMP failover reliability. Enter the address "0.0.0.0" to
indicate list is complete, if entering less than six targets.

11

You will need to press Enter after you enter each IP address.

Example
Enter ping target #1:

192.168.14.11[Enter]

Enter ping target #2:

192.168.14.21 [Enter]

Enter ping target #3:

192.168.14.41 [Enter]

Enter ping target #4:

0.0.0.0 [Enter]

Note: Do not use this server's own IP address as a ping
target.

12

Is this IPMP group configuration acceptable
(Y/N)
Select Y and press Enter.