MCS 4-server Sun Fire V100 Solaris Installation and Commissioning Guide

37

Copyright © 2006 Nortel Networks

4

Enter a new user password at the Enter your NEW
password:

prompt. The password will be displayed as

asterisks.

5

Re-enter the new user password at the Re-Enter your NEW
password:

prompt. The password will be displayed as

asterisks.

6

To change the superuser password for the unit, do the following:

a

Access the Configuration Command Mode.

b Enter the password command at the Config:0 >> prompt.

c

Enter a new superuser password at the Enter your NEW
password:

prompt. The password will be displayed as

asterisks.

d Re-enter the new superuser password at the Re-Enter

your NEW password:

prompt. The password will be

displayed as asterisks.

Procedure 8 Accessing the MRV LX terminal server

At the management pc,

1

Select Start -> Programs -> Accessories -> Communications
-> HyperTerminal.exe

2

Name the HyperTerminal Session: termserv [Enter]

3

Ensure that the appropriate COM port is set and that the
terminal emulation is set to VT100.

Note 1: You may be asked for the following parameters:

9600 baud rate

8 data bits / second

parity - None

stop bit - 1

Flow control - None

Note 2: Press Enter until you receive a log-in prompt. You
may need to press Enter several times before the prompt
appears.

4

Log in to the HyperTerminal: access [Enter]

Note: The letters do not appear when you type them. You are
typing them in blind.

5

Enter your username: admin [Enter]

6

To change security at the prompt, type set priv [Enter]