SCSI Commands

5-4

Quantum DLT 7000 Tape System

5.1.2 Command Descriptor Block

An initiator communicates with the drive by sending a 6- or 10-byte Command
Descriptor Block that contains the parameters for the specific command. The
SCSI command's operation code is always the first byte in the Command
Descriptor Block and a control field is the last byte. For some commands, the
Command Descriptor Block is accompanied by a list of parameters sent during
the DATA OUT phase. Figure 5–1 shows the format of a typical 6-byte
Command Descriptor Block. Table 5–2 contains a description of the Command
Descriptor Block fields.

Bit

Byte

7

6

5

4

3

2

1

0

0

Operation Code

1

Logical Unit Number

(LUN)

(MSB)

Logical Block Address

(LBA)

2 - 3

Logical Block Address

(LBA)

(LSB)

4

Transfer Length, Parameter List Length, or Allocation Length

5

Control

NOTE: Unless otherwise specified, all reserved bits indicated in the commands are 0.

Figure 5–1 Typical Command Descriptor Block - Data Format