Log sense command (4dh) (continued) – Quantum Instruments DLT 7000 User Manual

Page 153

Advertising
background image

SCSI Commands

Quantum DLT 7000 Tape System

5-49

LOG SENSE Command (4Dh) (continued)

Bit

Byte

7

6

5

4

3

2

1

0

0 -1

(MSB)

Parameter Code

(LSB)

2

DU

DS

TSD

ETC

TMC

Rsv’d

LP

3

Parameter Length

4 - n

(MSB)

Hex ASCII String for Event n

(LSB)

Figure 5–21 Log Parameters Format for Last n Error Events LOG SENSE Page

Table 5–23 Log Parameters for Last n Error Events LOG SENSE Page Field Descriptions

Field Name

Description

Parameter Code

Parameter Code values are assigned from 0 to 27 (decimal), where 0 is the
oldest event stored and the highest Parameter Code returned is the most
recent event.

Hex ASCII String
for Event n

The text of the parameter includes a “Packet #” that is a value from 0 to
255. This internal number is assigned when the packet is written to
EEPROM. A value of 0 is normally the oldest packet, but packet numbers
can wrap around back to 0 after reaching 255. For a detailed description of
the packet string, see Appendix B.

Advertising