Quantum Instruments DLT 7000 User Manual

Page 29

Advertising
background image

General Description and Specifications

Quantum DLT 7000 Tape System

1-5

1.3.6 Environmental Specifications

The following tables provide the operating, non-operating, storage and shipping
environmental specifications for the DLT 7000 tape system.

Table 1

−4 DLT 7000 Environmental Specifications

Specification

Operating Limits

Non-Operating Limits
(Power On; No Tape Loaded)

Wet Bulb Temperature

25°C (77°F)

25°C (77°F)

Dry Bulb Temperature
Range

10

°

C to 40

°

C (50

°

F to 104

°

F)

10

°

C to 40

°

C (50

°

F to 104

°

F)

Temperature Gradient

11

°

C (52°F) /hour (across range)

15

°

C (59°F) /hour (across range)

Temperature Shock

10

°

C (50°F) (over two minutes)

15

°

C (59°F) (over two minutes)

Relative Humidity

20% to 80% (non-condensing)

10% to 90% (non-condensing)

Humidity Gradient

10% / hour

10% / hour

Altitude

Normal Pressure from -500 feet
to 30,000 feet

Airflow Velocity

125 Linear Feet per Minute
(LFM) measured directly in front
of the front bezel

Table 1

−5 DLT 7000 Storage and Shipping Specifications

Description

Storage (Unpacked or Packed)

Shipping

Dry Bulb Temperature

-40 to 66°C (-40 to 150°F)

-40 to 150°F(-40 to 66°C)

Wet Bulb Temperature

46°C (114°F)

114°F (46°C)

Temperature Gradient

20°C (68°F) /hr with 5° margin
across the range

25°C (77°F) /hr with 5° margin
across the range

Temperature Shock

15°C (59°F) /hr with 5° margin
over 2 minutes

15°C (59°F) /hr with 5° margin
over 2 minutes

Relative Humidity

10 to 95%, non-condensing

10 to 95%, non-condensing

Humidity Gradient

10%/hr

10%/hr

Advertising