Quantum DLT 7000 Tape System

C-1

Appendix C

UPDATING THE FIRMWARE

This chapter explains how to update the tape drive’s PCBA-resident firmware.

C.1

OVERVIEW

Using the tape drive’s front panel and a tape with the updated firmware image,
you can update the tape drive’s PCBA-resident firmware.

CAUTION

If a powerfail occurs during the firmware update process (when the
new image is actually being programmed into the FLASH EEPROMs),
the tape drive’s PCBA will be rendered unusable. When performing
a firmware update, take all possible precautions to prevent power
failure to the tape drive.

C.2

CREATING A FIRMWARE UPDATE TAPE

To update the tape drive’s PCBA firmware, you need a tape cartridge with a copy
of the new firmware image. The firmware image must be byte-written without
compression onto the tape using the appropriate block size as defined in Table C-
1. The image must be “copied” onto the tape instead of using the backup utility.

Table C-1 Block Size Used for Firmware Update Tape

Tape Format

Density

Upgrade Tape Block

DLTtape III

2.6 GB 6.0
GB 10.0 GB

4 Kbytes Multiple 4
Kbytes Multiple 4
Kbytes Multiple

DLTtape IIIxt

15.0 GB

4 Kbytes Only

DLTtape IV

20.0 GB
35.0 GB

4 Kbytes Only 8
Kbytes Only