Quantum Instruments DLT 7000 User Manual

Page 44

Advertising
background image

Hardware Implementation

2-6

Quantum DLT 7000 Tape Drive

2.2.2 Configure the Rackmount Drive for TERMPWR (Single-Ended Only)

A SCSI bus must be terminated at each end of the bus. At least one device must
supply terminator power (TERMPWR). Quantum recommends that every device
on the SCSI bus be configured to supply TERMPWR to ensure that there is a
sufficient level of voltage along the SCSI bus.
Install a jumper across Pins 3 and 4 (Figure 2-2) to enable TERMPWR.

Figure 2-2 DLT 7000 TERMPWR and Parity Check Jumper Locations (Rackmount

Version Shown)

2.2.3 Configure The Rackmount Drive for Parity Checking

The default setting for DLT 7000 tape drives is to have parity checking enabled.
If the system to which you are configuring the rackmount tape drive does not
generate SCSI parity, disable parity checking by installing a jumper across Pins 1
and 2 on the parity check connector as shown in Figure 2-2.

1
2

25
26

1
2

Install Jumper on Pins 3-4
to enable TERMPWR.

Front Panel

TERMPWR

Parity Check

Install Jumper on Pins 1-2
to disable Parity Checking.

17
18

Advertising