Log sense command (4dh) (continued) – Quantum Instruments DLT 7000 User Manual
Page 164
Advertising

SCSI Commands
5-60
Quantum DLT 7000 Tape System
LOG SENSE Command (4Dh) (continued)
Bit
Byte
7
6
5
4
3
2
1
0
0
Parameter Code
1
Reserved
2
DU
DS
TSD
ETC
TMC
Rsv’d
LP
3 - 7
(MSB)
Time Stamp
(LSB)
8 - 11
(MSB)
Media ID
(LSB)
12
Sense Key
13
Additional Sense Key
15
Additional Error Information
Figure 5–28 Log Parameters Format for Device Wellness LOG SENSE Page (Parameters
0000h – 000Fh)
Advertising