Quantum Instruments DLT 7000 User Manual

Page 36

Advertising
background image

General Description and Specifications

1-12

Quantum DLT 7000 Tape System

1.3.12 Electromagnetic Emissions

The integratible version of the drive complies with FCC Class A in a standard
enclosure; the tabletop version complies with the FCC Class B limits.

1.3.13 Electromagnetic Interference (EMI) Susceptibility

The following table provides regulations and certifications held by the tape
drives.

Table 1–14 EMI Regulations and Certifications

Type

Regulation/Certification

For EMI Emissions

CSA 108.8
EEC Directive 89/336

EN550022 and National
Standards

BS6527 (UK)
NEN55022 (Netherlands)
VDE 0971 Class B (Germany)
CE Mark

Cispr22 Class B

FCC Rules Part 15B
Class B Certification

1.3.14 Conducted Emissions

Limits for Class B equipment are in the frequency range from 0.15 to 30 MHz.
The limit decreases linearly with the logarithm of the frequency in the range
from 0.15 to 0.50 MHz.

Table 1-15 Conducted Emissions

Frequency Range

Limits dB

Quasi-peak

Average

0.15 to 0.050 MHz

66 to 56*

56 to 46

0.50 to 5 MHz

56

46

5 to 30 MHz

60

50

* The limit decreases with the logarithm of the frequency.

Advertising