Quantum Instruments DLT 7000 User Manual

Page 224

Advertising
background image

SCSI Commands

5-120

Quantum DLT 7000 Tape System

MODE SENSE (6) / (10) Command (1Ah / 5Ah) (continued)

Table 5–57 Device Configuration Page - Field Descriptions (continued)

Field Name

Description

SOCF

Stop on Consecutive Filemarks. Set to 0.

RBO

Recover Buffer Order. Set to 0.

REW

Report Early Warning. Set to 0 (do not report early warning EOM on
reads).

Gap Size

Not supported. Set to 0.

EOD Defined

End of Data. Set to 00h.

EEG

Enable EOD Generation Bit. Set to 1 to indicate that the drive
generates an EOD. The drive generates an EOD mark before any
change of direction following a WRITE-type operation.

SEW

Synchronize at Early Warning. Set to 1.

Buffer Size at Early
Warning

Not supported; must be 0.

Select Data Compression
Algorithm

If set to 1, data compression is enabled. If 0, data compression is
disabled.