background image

SCSI Commands

Quantum DLT 7000 Tape System

5-35

LOG SELECT Command (4Ch) (continued)

5.7.3 Log Select Page Format

Each log page begins with a 4-byte header followed by

n number of log parameter

blocks (one block for each parameter code). Each block, except for parameter
code 05h is comprised of 8 bytes. The parameter block for code 05h is 12 bytes.

Bit

Byte

7

6

5

4

3

2

1

0

0

Reserved

Page Code

1

Reserved

2 - 3

(MSB)

Page Length

(LSB)

Figure 5–14 LOG SELECT Log Page Header Format

Table 5–17 LOG SELECT Log Page Header Field Descriptions

Field Name

Description

Page Code

The Page Code specifies for which Log Page this LOG SELECT command is
directed.

Page Length

The Page Length field specifies the total number of bytes contained in
this log page, not including the four bytes that make up the header.