SCSI Commands

5-10

Quantum DLT 7000 Tape System

Table 5–5 DATA-Phase Command Contents (Continued)

Command

Length in CDB

Data Out (To

Drive)

Data In

(To Initiator)

REWIND

0

---

---

SEND DIAGNOSTIC

Parameter List

Diagnostic Page

---

SPACE

0

---

---

TEST UNIT READY

0

---

---

VERIFY

Transfer

Data

---

WRITE

Transfer

Data

---

WRITE BUFFER

Parameter List

Microcode Image

Data

---

WRITE FILEMARKS

---

---

---

5.1.5 Unit Attention Condition

Queued Unit Attentions are implemented on the Quantum DLT 7000 tape drive
and are maintained separately for each valid LUN for each initiator. Unit
Attentions are created in each of the following circumstances:

At Power On

At Bus Reset

At Bus Device Reset message

When the medium may have changed asynchronously

When another initiator changes the Mode Parameters

When a firmware (microcode) update has completed

Two queued Unit Attentions are not unusual. For example, if a unit is powered
up and a tape cartridge is loaded, Power Up and Not-Ready to Ready Transition
Unit Attentions are created. Due to the limited number of Unit Attention
buffers, if an initiator does not clear Unit Attentions queued for it, at some
point the tape drive stops generating new Unit Attentions for that initiator-
logical unit combination (existing ones will be left queued, however).
A LOAD command does not generate a Unit Attention for the initiator that
issued the command since the transition to Ready is synchronous.