SCSI Commands
Quantum DLT 7000 Tape System
5-123
MODE SENSE (6) / (10) Command (1Ah / 5Ah) (continued)
5.10.3.7 TapeAlert Page (1Ch)
The TapeAlert configuration settings can be read via the MODE SENSE
command’s TapeAlert Page.
Bit
Byte
7
6
5
4
3
2
1
0
0
PS (0)
0
Page Code (1Ch)
1
Additional Page Length (0A)
2
Perf
Reserved
DExcpt
Test
Rsvd
LogErr
3
Reserved
MRIE
4 – 7
(MSB)
Interval Timer
(LSB)
8 – 11
(MSB)
Report Count / Test Flag Number
(LSB)
Figure 5–59 TapeAlert Page Format Descriptor - Data Format