Quantum Instruments DLT 7000 User Manual

Page 207

Advertising
background image

SCSI Commands

Quantum DLT 7000 Tape System

5-103

MODE SENSE (6) / (10) Command (1Ah / 5Ah) (continued)

Table 5–49 MODE SENSE Control Descriptor Block - Field Descriptions

Field Name

Description

DBD

Disable Block Descriptors. If 0, device returns the block descriptor
data. If set to 1, block descriptor information is not returned.

PC

Page Control. The Page Control field indicates the type of page
parameter values to be returned to the host.

PC Description

00 Report Current Values

01 Report Changeable Values

10 Report Default Values

11 Report Saved Values

Page Code

This field allows the host to select any specific page or all of the
pages supported by the drive.

Allocation Length

This field specifies the number of bytes that the host has allocated for
returned MODE SENSE data. An allocation length of zero indicates
that the drive will return no MODE SENSE data. This is not considered
an error, and GOOD status is returned.

MODE SENSE may be either MODE SENSE (6) or MODE SENSE (10). MODE
SENSE (6) data contains a 4-byte header followed by one 8-byte block descriptor,
followed by zero or more variable length pages, depending on the Page Code and
Allocation Length.

Advertising