Quantum Instruments DLT 7000 User Manual

Page 37

Advertising
background image

General Description and Specifications

Quantum DLT 7000 Tape System

1-13

1.3.15 Radiated Emissions

Limits of radiated interference field strength, in the frequency range from 30
MHz to 30 GHz at a test distance of 3 and 10 meters, for Class B equipment are
listed in the following table.

Table 1-16 Radiated Emissions

Frequency Range

Quasi-peak limits dB (µV/m)

Quasi-peak

Average

30 to 230 MHz

30

40

230 to 1000 MHz

37

46

Above 1000 MHz

N/A

54

* The limit decreases with the logarithm of the frequency.

1.3.16 Susceptibility

The following table lists radiated, magnetic radiated, and conducted
susceptibility for the tape drive.

Table 1-17 Radiated, Magnetic Radiated, and Conducted Susceptibility

Radiated - High Frequency, Electric Fields, 1 to 1000 MHz

3 V/m (rms) 80% modulated 1 kHz

No errors, no screen distortion
S/W recoverable errors No
hardware failure

Magnetic Radiated - Low Frequency, Magnetic Fields, 10 to 3000 kHz

100 dB (pt) @ 10 kHz declining to 80 dB (pt) @
1 Mhz

No errors, no screen distortion

Conducted (The transient voltage is the actual peak voltage above the normal ac voltage
from the power source. The maximum energy in a single pulse from the transient
generator must be limited to 2.5 W)

Fast Transient (Bursts) for
Power and Data Cables

2 kV

S/W recoverable errors No
hardware failures

High Energy Transient
Voltage for Power Cables

1.2 kV
2.5 kV

No errors
S/W recoverable errors No
hardware failure

Low-Level Conducted
Interference

3 V (rms) 80%
modulated 1 kHz

No errors S/W
recoverable errors No
hardware failure