Read position command (34h) (continued) – Quantum Instruments DLT 7000 User Manual

Page 242

Advertising
background image

SCSI Commands

5-138

Quantum DLT 7000 Tape System

READ POSITION Command (34h) (continued)

Data from READ POSITION takes the following format:

Bit

Byte

7

6

5

4

3

2

1

0

0

BOP

EOP

Reserved

BPU (0)

Reserved

1

Partition Number

2 - 3

Reserved

4 - 7

(MSB)

First Block Location

(LSB)

8 - 11

(MSB)

Last Block Location

(LSB)

12

Reserved

13 - 15

(MSB)

Number of Blocks in Buffer

(LSB)

15 - 19

(MSB)

Number of Bytes in Buffer

(LSB)

Figure 5–68 READ POSITION - Data Format

Advertising