SCSI Commands

5-108

Quantum DLT 7000 Tape System

MODE SENSE (6) / (10) Command (1Ah / 5Ah) (continued)

Table 5–51 MODE SENSE Block Descriptor - Field Descriptions (continued)

Field Name

Description

Number of
Blocks

This field is sent as 0, indicating that all of the remaining logical blocks on the tape
have the medium characteristics specified by the block descriptor.

Block Length

This field specifies the length (in bytes) of each logical block transferred over the
SCSI bus. A block length of 0 indicates that the length is variable (as specified in the
I/O command). Any other value indicates the number of bytes per block that are
used for READ, WRITE, and VERIFY type commands that specify a fixed bit of 1
(fixed block mode).

5.10.3 MODE SENSE Mode Pages

The following figure depicts the variable length page descriptor.

Bit

Byte

7

6

5

4

3

2

1

0

0

PS

0

Page Code

1

Additional Page Length

2

Page Defined or Vendor-Unique Parameter Bytes

Figure 5–52 MODE SENSE Page Descriptor - Data Format

Descriptions of the MODE SENSE page descriptor fields are provided in the
following table. Detailed descriptions of each of the MODE SENSE Pages follow.