SCSI Commands

Quantum DLT 7000 Tape System

5-75

MODE SELECT (6) / (10) Command (15h) / (55h) (continued)

5.9.3 Disconnect / Reconnect Page (02h)

The Disconnect / Reconnect Page controls the drive’s behavior on the SCSI bus
and allows an initiator to tune bus performance.

Bit

Byte

7

6

5

4

3

2

1

0

0

PS (0)

0

Page Code (02h)

1

Additional Page Length (0Eh)

2

Buffer Full Ratio

3

Buffer Empty Ratio

4 - 5

(MSB)

Bus Inactivity Limit

(LSB)

6 - 7

(MSB)

Disconnect Time Limit

(LSB)

8 - 9

(MSB)

Connect Time Limit

(LSB)

10 - 11

(MSB)

Maximum Burst Time

(LSB)

12

Reserved

DTDC

13 – 15

Reserved

Figure 5–38 Disconnect / Reconnect Page - Data Format