Table 297 device ha logs – ZyXEL Communications 200 Series User Manual

Page 797

Advertising
background image

Appendix A Log Descriptions

ZyWALL USG 100/200 Series User’s Guide

797

Can't get BROADCAST

address of %s

interface

The connectivity check process can't get broadcast address of
interface
%s: interface name

Can't use MULTICAST IP

for destination

The connectivity check process can't use multicast address to check
link-status.

The destination is

invalid, because

destination IP is

broadcast IP

The connectivity check process can't use broadcast address to check
link-status.

Can't get MAC address

of %s interface!

The connectivity check process can't get MAC address of interface.
%s: interface name

To send ARP REQUEST

error!

The connectivity check process can't send ARP request packet.

The %s routing status

seted to DEAD by

connectivity-check

The interface routing can't forward packet.
%s: interface name

The %s routing status

seted ACTIVATE by

connectivity-check

The interface routing can forward packet.
%s: interface name

Table 297 Device HA Logs

LOG MESSAGE

DESCRIPTION

Device HA VRRP Group

%s has been added.

An VRRP group has been created, %s: the name of VRRP group.

Device HA VRRP group

%s has been modified.

An VRRP group has been modified, %s: the name of VRRP group.

Device HA VRRP group

%s has been deleted.

An VRRP group has been deleted, %s: the name of VRRP group.

Device HA VRRP

interface %s for VRRP

Group %s has changed.

Configuration of an interface that belonged to a VRRP group has been
changed, 1st %s: VRRP interface name, 2ed %s: %s: the name of
VRRP group.

Device HA syncing from

%s starts.

Device HA Syncing from Master starts when user click "Sync Now"
using Auto Sync, %s: The IP of FQDN of Master.

%s has no file to

sync, Skip syncing it

for %s.

There is no file to be synchronized from the Master when syncing a
object (AV/AS/IDP/Certificate/System Configuration), But in fact, there
should be something in the Master for the device to synchronize with,
1st %s: The syncing object, 2ed %s: The feature name for the syncing
object.

Master configuration

is the same with

Backup. Skip updating

it.

The System Startup configuration file synchronized from the Master is
the same with the one in the Backup, so the configuration does not
have to be updated.

%s file not existed,

Skip syncing it for %s

There is no file to be synchronized from the Master when syncing a
object (AV/AS/IDP/Certificate/System Configuration), But in fact, there
should be something in the Master for the device to synchronize with,
1st %s: The syncing object, 2ed %s: The feature name for the syncing
object.

Table 296 Connectivity Check Logs (continued)

LOG MESSAGE

DESCRIPTION

Advertising