ZyXEL Communications 200 Series User Manual

Page 806

Advertising
background image

Appendix A Log Descriptions

ZyWALL USG 100/200 Series User’s Guide

806

AUX Interface

disconnecting failed.

This AUX interface is

not enabled.

The AUX interface is not enabled and a user tried to use the
disconnect aux command.

Please type phone

number of interface

AUX first then dial

again.

A user tried to dial the AUX interface, but the AUX interface does not
have a phone number set.

Please type phone

number of Interface

AUX first then

disconnect again.

The AUX interface does not have a phone number set and a user tried
to use the disconnect aux command.

Interface %s will

reapply because Device

HA become active

status.

Device-ha became active and is using a PPP base interface, the PPP
interface must reapply, %s is the interface name.

Interface %s will

reapply because Device

HA is not running.

Device-ha was deleted and free PPP base interface, PPP interface
must reapply, %s is the interface name.

Interface %s will stop

connect because Device

HA become standby

status.

When device-ha is stand-by and use PPP base interface, PPP
interface connection will stop, %s: interface name.

Create interface %s

has been failed.

When PPP can't running fail, %s: interface name.

Base interface %s is

disabled. Interface %s

is disabled now.

When user disable ethernet, vlan or bridge interface and this interface
is base interface of PPP or virtual interface. PPP and virtual will disable
too. 1st %s is interface name, 2nd %s is interface.

Interface %s has been

changed.

An administrator changed an interface’s configuration. %s: interface
name.

Interface %s has been

added.

An administrator added a new interface. %s: interface name.

Interface %s is

enabled.

An administrator enabled an interface. %s: interface name.

Interface %s is

disabled.

An administrator disabled an interface. %s: interface name.

%s MTU > (%s MTU - 8),

%s may not work

correctly.

An administrator configured a PPP interface, PPP interface MTU >
(base interface MTU - 8), PPP interface may not run correctly because
PPP packets will be fragmented by base interface and the peer will not
receive correct PPP packets. 1st %s: PPP interface name, 2nd %s:
ethernet interface name.

(%s MTU - 8) < %s MTU,

%s may not work

correctly.

An administrator configured ethernet, vlan or bridge and this interface
is base interface of PPP interface. PPP interface MTU > (base
interface MTU - 8), PPP interface may not run correctly because PPP
packets will be fragmented by base interface and peer will not receive
correct PPP packets.1st %s: Ethernet interface name, 2nd %s: PPP
interface name.

Table 301 Interface Logs (continued)

LOG MESSAGE

DESCRIPTION