· Press the Auto Lake Screen Lake Fill & Filter touch key on the Register Access screen to open

the first Accessories screen.

 

 

 

· N80:0 is the minimum flow (in GPM) to flush. The pump station flow rate that must be met before

the automatic lake screen is allowed to flush. The default value is normally between 45 and 90
GPM.

 

· N80:1 is the time (in minutes) between Auto Lake Screen (ALS) Strainer flushes. The normal

default value is 30.

 

· N80:2 is the flush duration in seconds. Normal default value is 10 to 15 seconds.

 

· Tap the value field next to any of these registers and the calculator/keypad pops-over the screen.