Repair of faults and errors – Xylem IM131R01 AQUAVAR AV II User Manual

Page 74

Advertising
background image

Table 13: AQUAVAR Electrical Fault Codes

(continued)

Fault Code

Fault Name

Possible Cause(s)

How to Recover

23

Motor Underload The load on the motor is so

Check the motor and load.

insufficient (for example, a
broken conveyor belt) that a
fault occurs.

24

TSP 10 V Ref

10 V reference for the analog

• Ensure that the total load on

input is overloaded.

the +10 terminal does not
exceed 20 mAdc.

• Check for correct connection of

devices to the +10 terminal.

• Check for short circuits

associated with devices
connected to the +10 terminal.

• Consult factory.

25

EE Ref Checksum Parameter restoring error due

Reset the fault and attempt a

to interference fault or

restart. If fault persists, contact

component failure.

the factory.

26

EE Par Checksum Parameter restoring error due

Reset the fault and attempt a

to interference fault or

restart. If fault persists, contact

component failure.

the factory.

27

EEPROM

Parameter restoring error due

Reset the fault and attempt a

Checksum

to interference fault or

restart. If fault persists, contact

component failure.

the factory.

28

Outpt Phase Loss

Current measurement detected

Check motor cables.

a motor phase with no current.

29

Precharge Fault

Consult factory.

Consult factory.

30

TRIN Flt (ASIC)

Consult factory.

Consult factory.

31

Satur Flt (ASIC)

Consult factory.

Consult factory.

32

Empty Trp (ASIC)

Consult factory.

Consult factory.

33

Appl Change

Consult factory.

Consult factory.

34

High Unbal Curr

Consult factory.

Consult factory.

35

MCP Software

Consult factory.

Consult factory.

36

Loss of Ref

The drive detected the loss of

Restore the reference signal.

(Fault)

the reference signal.

37

Loss of Ref

The drive detected the loss of

Restore the reference signal.

(Warning)

the reference signal.

38

Broken Wire Trip

The drive detected a broken

Check the control wiring for a

(Fault)

wire to Analog Input 1.

broken wire and replace.

39

Broken Wire Trip

The drive detected a broken

Check the control wiring for a

(Warning)

wire to Analog Input 1.

broken wire and replace.

Repair of Faults and Errors

73

Advertising