Differential pressure transmitter, Appendix a, Series pd-39s – Xylem IM131R01 AQUAVAR AV II User Manual
Page 83: Specifications, Type sealed gauge
![background image](/manuals/310496/83/background.png)
Differential
Pressure Transmitter
Series PD-39S
The sensors of this differential transmitter are two
piezoresistive silicon pressure sensors, mounted
on a tape (TAP), freely floating in an oil chamber.
The pressure is transferred to the sensor by a
separating steel diaphragm in the oil chamber.
82
Appendix A
Specifications
Measuring Range (FS):
0,4 bar
4 bar
10 bar
Differential
(other ranges upon request)
Over-Pressure (PMAX):
16 bar
16 bar
16 bar
Single-sided
Class of protection:
IP 65
IP 65
Type
Sealed gauge:
Output-Signal:
4-20mA; 2 wire
Supply:
8-28 VDC
Load resistance:
max. 50Ω at supply voltage = 10VDC
Linearity:
± 0.2% FS; max ±0.5% FS
Stability:
± 0.1% FS; max ± 0.2% FS
Operating Temperature:
-20° to +80° C
Storage Temperature:
-40° to +120° C
Material: Body and diaphragm: 1.4435 stainless steel
P -
P +
= 95
60
26
44
40
Screw joint and cover:
Diagram 23
Plug: mPm 193
incl. 2 m cable
Cable:
Out (white)
+ Vcc (brown)
Screen