Xylem GLS GLV User Manual

Page 27

Advertising
background image

en

27

7.1.2

Major inspection

In addition to the operations in section 7.1.1, follow this operations:

Component to be inspected

Operation

Motor shaft bearings

Replace the bearings with new bearings.

Mechanical seals

Replace with new mechanical seals.

7.1.3

Change the oil

Change the oil at least once a year or when the oil is dirty. Depending on the electric pump model, 1 or 2 oil plugs are present

( section 10.10).

The oil chamber can be under pressure. Hold a rag over the oil plug to prevent oil from spraying out.

7.1.3.1

Version with 1 plug

Place the electric pump in an horizontal position with the oil plug facing upward. Unscrew the oil plug. Place a container under

the electric pump, turn the electric pump and drain all the oil.

Use medical white oil of paraffin type that fulfills FDA 172.878 (a) and viscosity close to VG32. Replace the O-ring of the oil

plug. Fill with oil (approximate quantity 0.6 liters). Screw and tighten the oil plug (tightening torque 10-40 Nm).

7.1.3.2

Version with 2 plugs

Place the electric pump in an horizontal position with the oil plug facing upward. Unscrew the oil plug. If the electric pump has a

hole marked “oil out”, it’s important to use this hole to drain the oil. Place a container under the electric pump and turn the

electric pump. Unscrew the other oil plug. If this hole is marked “oil in”, raise the pump upright for a short period of time during

drainage in order to drain all the oil.

Use medical white oil of paraffin type that fulfills FDA 172.878 (a) and viscosity close to VG32. Replace the O-rings of the oil

plugs. Screw an oil plug in the hole that faces downwards or is marked “oil out”, and tighten (tightening torque: 10-40 Nm). Fill

with oil through the hole on the opposite side or the hole marked “oil in”. If the hole is marked “oil in”, slightly tilt the electric

pump and lower it again in order to fill the electric pump with the correct oil quantity (approximate quantity 2 liters).

7.1.4

Checking the electric motor

If you have any doubts regarding the motor conditions, measure the isolation resistance to ground, which must exceed

5

Megaohm (MΩ). If you believe that there may be water inside the motor, please contact our Sales and Service Department.

7.1.5

Replacing the impeller

Please contact our Sales and Service Department.

7.1.6

Replacing the mechanical seals

Please contact our Sales and Service Department.

7.2

Customer service

Please contact our Sales and Service Department for any information or service you may require.

7.3

Spare parts

Always specify the exact electric pump type and identification code when requesting technical

information or spare parts from our Sales and Service Department.

Use only original spare parts to replace any worn or faulty components. The use of unsuitable spare

parts may cause malfunctions, damage and injuries.

Please always refer to our Sales and Service Department for modifications on the electric pump or on the installation.

Refer to the diagrams in section 10.11.

8.

Troubleshooting

Information for users and maintenance personnel

PROBLEM

PROBABLE CAUSE

POSSIBLE SOLUTION

No power supply.

Restore the power supply.

The electric pump does not start.

The main switch is on.

Triggering of thermal relay or motor

protector found in the electric control

panel.

Reset the thermal protector.

Pump or auxiliary circuits protection

fuses blown.

Replace fuses.

Incorrect connection to capacitors

(single-phase version)

Check the connections in the electric

panel

Triggering of start/stop device ( float).

Triggering of protection device against

dry running (float).

Check the water level in the tank. If

everything is in order, check the

protection device and its connection

cables.

Triggering of motor thermal sensor

Wait for the pump motor to cool down.


Electric motor failure.

section 7.1.4

Power supply cable is damaged.

The electric pump starts up but the

thermal protector is immediately

Electric motor short circuit.

Contact our Sales and Service

Department.

WARNING