Multimeter specifications – B&K Precision 2516 - Manual User Manual

Page 152

Advertising
background image

152

Multimeter Specifications

All specifications are based on operating at temperatures 23 ± 5°C

and relative humidity < 75%.

Accuracy is based on ± (% of reading + offset)


Display

Resolution

6000 counts

Measurement

Function

DC voltage, AC voltage, resistance, diode, continuity,
capacitance, DC current, AC current

Max. Input

Voltage

AC: 750 V (20 Hz - 1 kHz)

DC: 1000 V

Max. Input

Current

AC: 10 A (20 Hz - 1 kHz)
DC: 10 A

Input Impedance

10 MΩ

Max. Input

Voltage between

Multimeter input

reference and

ground

CAT I, CAT II 600 V RMS
CAT III 300 V RMS

Max. input

Voltage for

Multimeter input

ports

Voltage/Resistance/Capacitance port: DC 1000 V, AC
750 V RMS

Current port (mA): AC 250 V, 600 mA

Current port (10A): AC 250 V, 10 A



DC Voltage

Range

Resolution

Accuracy

60.00 mV

10 µV

± (1 % + 15 digit)

600.0 mV

100 µV

± (1 % + 5 digit)

6.000 V

1 mV

60.00 V

10 mV

600.0 V

100 mV

1000 V

1 V

Advertising