Maximum input voltage to CH1 and CH2 BNC via 1X/10X probe PR150SA

(included with models 2511 and 2512) – CATII 300V RMS

Scope Input – CATII 300V RMS

Meter Input – CATII 600V RMS, CATIII 300V RMS



NOTE:

Voltage ratings are given as “working voltage”. They
should be read as Vac-rms (50 – 60 Hz) for AC sine
wave applications and as Vdc for DC applications.




Maximum Floating Voltage

These apply to models 2515 and 2516 only, which have channel isolation
that allows for floating measurements.

Maximum floating voltage from input CH1 and CH2 to earth ground

– CATII 1000V RMS, CATIII 600V RMS

Maximum floating voltage between CH1 and CH2 reference – CATII

1000V RMS, CATIII 600V RMS

The following applies to all models:

Maximum floating voltage from multimeter reference to earth

ground – CATII 600V RMS, CATIII 300V RMS

NOTE:

Voltage ratings are given as “working voltage”. They
should be read as Vac-rms (50 – 60 Hz) for AC sine
wave applications and as Vdc for DC applications.