Recorder specifications – B&K Precision 2516 - Manual User Manual

Page 154

Advertising
background image

154

(2)(3)

DC and AC Current

Range

Resolution

Accuracy

60.00 mA

10 µA

± (1 % + 5 digit)

600.0 mA

100 µA

6.000 A

1 mA

± (1.5 % + 5 digit)

10.00 A

10

mA

2. For 10 A terminal, > 6 A DC or AC rms for 10 seconds ON and 15 minutes
OFF.

3. For AC current ranges, frequency is verified for 20 Hz to 1 kHz.

Recorder Specifications



Scope Trend Plot

Display Mode

Full view, Normal

Record Length

800K points, > 24 hours

Number of
Channels

2


Multimeter Trend Plot
Display Mode

Full view, Normal

Record Length

1.2 M dots, > 24 hours

Number of Channels

1


Scope Recorder
Display Mode

Full view, Normal

Max. Record Length

Single Channel: 7M points
Dual Channel: 3.5 M points

Number of Channels

2

Maximum Record Size
to External Storage

4GB, 3000 hours


Advertising