16-bit field, the transmit PDO is always sent after the "event timer" expires. The value is written in subindex

5 of a transmit PDO. The data transfer also takes place with no change to data. The range is between 1-

65536 ms.

Object 1A00h: 1

st

TPDO Mapping Parameter

This object contains the mapping parameter of the 1

st

transmit PDO.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Number of sub indices

Unsigned 8

2

ro

yes

1

1st mapped object

Unsigned 32

60040020h

rw

yes

Object 1A01h: 2

nd

TPDO Mapping Parameter

This object contains the mapping parameter of the 2

nd

transmit PDO.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0

Number of sub indices

Unsigned 8

2

ro

yes

1 2

nd

mapped object

Unsigned 32

60040020h

rw

yes

Object 1F50h: Download Program Area

This is a special bootloader object, that has functionality for single turn encoders without connection cap

only. (see Bootloader chapter)

Use this entry to download your Intel hex file with the programming data. Detailed information about

Domain download and Block transfer in CiA Draft Standard 301 Application Layer and communication

Profile.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0h

Number of sub indices

Unsigned 8

2h

ro

Yes

1h

DOMAIN

wo

yes