2. Installation

2.1 Connection via Connection Cap

2.1.1 Signal Assignment

The rotary encoder is connected with two or three

cables depending on whether the power supply is

integrated into the bus cable or connected

separately. If the power supply is integrated into

the bus cable, one of the cable glands can be fitted

with a plug. The cable glands are suitable for cable

diameters from 6.5 up to 9 mm.

Tab. 1 Signal Assignment Connection Cap

Clamp

Description

Ground

+

24 V Supply voltage

-

0 V Supply voltage

G

CAN Ground

L

CAN Low

H

CAN High

G*

CAN Ground

L*

CAN Low

H*

CAN High

* are not connected, if terminal resistor is ON

(see next page)