Object 6200h: cyclic timer, Object 6300h: cam state register, Object 6301h: cam enable register – BEI Sensors MHK5 Absolute Hollow Shaft Encoder User Manual

Page 48: Object 6302h: cam polarity register

Advertising
background image

Version 07/10

BEI Sensors CANopen Manual serie M

48

Object 6200h: Cyclic timer

This object contains the value of the event timer of the corresponding TPDOs. The value can be changed

between 1-65538 ms.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0h

Cyclic Time

Unsigned 16

64h

rw

yes

The object 6200h is hard-wired to the objects 1800h subindex 5h and 2200h and provide the cycle time for

the cyclic mode. (See chapter Cycle Time and Event Timer)

Object 6300h: Cam state register

This object contains the cam state register. The subindices 1h to FEh contain the cam state of channel 1 to

254.

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0h

Number of sub indices

Unsigned 8

1h

ro

1h

Cam state channel 1

Unsigned 8

4h

romap

yes

Object 6301h: Cam enable register

This object contains the cam enable register

Subindex Description

Data Type

Default Value

Access

Restore after

BootUp

0h

Number of sub indices

Unsigned 8

1h

ro

1h

Cam enable channel 1

Unsigned 8

rw

yes

Object 6302h: Cam polarity register

This object contains the cam enable register

Subindex Description

Data Type

Default Value

Access

Restore after

Advertising
This manual is related to the following products: