Blind shaft (B)

Cable exit (cable diameter = 8 mm) or 5 pin M12 connector

Mounting instructions

The clamp ring should only be tightened if the

shaft of the driving element is inserted into the

hub shaft.

The diameter of the hollow shaft can be reduced

to 12mm, 10 mm or 8 mm by using an adapter

(this reducing adapter can be pushed into the

hollow shaft).

Maximum shaft movements of the drive element

are listed in the table.

Axial

Radial

static

± 0,3 mm

± 0,5 mm

dynamic

± 0,1 mm

± 0,2 mm

L

Single-Turn

72mm

Multi-Turn

81mm