The connection cap fulfills the function of a T-

coupler. From there the wiring must be done

according to the drawing on the left side. Please

note the assignment of incoming and outgoing bus

signals.

An activated bus termination

resistor will lead into a separation

of bus in and bus out signals!

Cable Connection

Remove screw, sealing and cone from the cable

gland. Remove 55 mm of the sheath and 50 mm of

the shielding. About 5 mm of the wires should be

de-isolated. Put screw, and sealing on the cable.

The cone should be mounted under the shielding

according to the figure 3. Put the whole cable into

the cable gland and tighten the screw.

2.1.2 Bus Termination in Connection Cap

If the encoder is connected at the end or beginning

of the bus the termination resistor must be

switched on. The termination resistor is switched

on when the switch is in the ON position.

Separation of Bus In and Bus Out

signals if termination resistor is

activated.

There is a resistor provided in the connection cap,

which must be used as a line termination on the

last device.

Resistor:

Last Device

Device X

Fig. 1 Connection cap bus in and bus out

Fig. 2 Cable preparation

Fig. 3 Cable connection

5 mm

5 mm

55 mm

50 mm