19 smart tuning function – IAI America CON-PGA User Manual

Page 105

Advertising
background image

5. Operation of CON Related Controllers

97

5.19 Smart Tuning Function

With the Smart Tuning Function, the following 2 operations can be performed.

1) Setting of maximum acceleration/deceleration speed considering the indicated transported load and

velocity

2) Setting of acceleration/deceleration speed to provide the shortest operation time figured out from the

indicated transported load and moving distance

(1) Setting of maximum acceleration/deceleration speed considering the indicated transported load and

velocity

It is the function to set the maximum acceleration/deceleration speed available at the indicated

transported load and velocity.

(2) Setting of acceleration/deceleration speed to provide the shortest operation time figured out from the

indicated transported load and moving distance

It is the function to set the combination of velocity and acceleration/deceleration that provide the

shortest operation time for the indicated moving distance in several patterns of selectable combinations

of the velocity and acceleration/deceleration with accordance with the transported load.

When 12.0 [Kg] is indicated for the transported load, for an instance, the combination of the velocity and

acceleration/deceleration to provide the shortest operation time for each moving distance is as shown

below:

1) When 30.00 [mm] is indicated

Ÿ

Velocity and acceleration for shortest operation time : 250.00 [mm/sec], 0.70 [G]

2) When 40.00 [mm] is indicated

Ÿ

Velocity and acceleration for shortest operation time : 300.00 [mm/sec], 0.50 [G]

(Note) The search of the combination of velocity and acceleration/deceleration for the shortest

operation time refers to the operation schedule time.

For a reference, the following table shows the list of the operation time for each moving distance.

List of Operation Time for Each Moving Distance

Carrier load

[Kg]

Movement

distance [mm]

Velocity

[mm/sec]

Acceleration/

Deceleration

[G]

Operation time

[msec]

250.00

0.70

156

30.00

300.00

0.50

161

250.00

0.70

196

12.0

40.00

300.00

0.50

195



Advertising
This manual is related to the following products: