7. Operation of MEC Related Controllers

208

The operating direction is shown by using an example of stopping at 2 points.

The current position of the axis is shown.

The speed of the axis is shown.

x

Instruction Vel:

Select [10%], [50%] or [100%] as the speed for trial operation. If the speed set on the

position setting screen is 600 mm/s, for example, the trial Operation peed will

become 600 mm/s if [100%] is selected, 300 mm/s if [50%] is selected, or 60 mm/s if

[10%] is selected.

x

Forward:

Touching [Forward] causes the actuator to move toward the end point.

x

Backward:

Touching [Backward] causes the actuator to move toward the start point.

x

Continuous:

Touching [Continuous] causes the actuator to move continuously until [Stop] is

touched.

If the actuator is set to stop at 2 points, it will move between the start point and end

point repeatedly.

If the actuator is set to stop at 3 points, it will move in the sequence of intermediate

point o end point o start point repeatedly.

x

Stop:

Touching [Stop] causes the actuator to stop.

x

Opp, Normal:

Touching [Opp] or [Normal] toggles the display mode between normal and reversed-

home.