5. Operation of CON Related Controllers

51

No.

Operation

Screen

Remarks

7 Next, touch the target position

of position No. 1.

When the numeric keypad

appears, touch [8], [0] and then

touch [ENT].

To reenter the value, touch

[ESC].

8

When registering a new position

data, the default values set by

user parameters are

automatically entered for the

velocity, acceleration,

deceleration, etc.
In this example, the default

value is 100 mm/s.

9 Next, touch No. "001" of

position No. 1.

10 Touch the value in the Push.

When the numerical keypad

appears, touch [3], [0] and then

touch [ENT].

To reenter the value, touch

[ESC].

11 Touch the value for the

positioning band.

When the numerical keypad

appears, touch [5] and then

touch [ENT].

To reenter the value, touch

[ESC].

12 Touch [Menu1].