IAI America CON-PGA User Manual

Page 134

Advertising
background image

6. Operation of SEP

Related Controllers

126

[3] Examples of position setting operations

Respective operations are explained by giving specific examples.

1) Setting of position, speed, acceleration and deceleration

An example of operation mode 0 (standard) is explained.

Set positions to move the actuator back and forth between 10.0 mm and 100.0 mm.

Forward end position: 100.0 mm, backward end position: 10.0 mm, back-and-forth speed:

50 mm/sec, back-and-forth acceleration: 0.3 G, back-and-forth deceleration: 0.3 G

No.

Operation

Screen

Remarks

1 On the SEP menu screen:

Touch [Pos.Edit].

2 If the password is other than

"0000," the password input

screen appears.

Input a password.

You can set a password for

position specification from

"Position edit password" on the

parameter edit screen.

3 Set the position, acceleration

and deceleration relating to the

backward end position.

Touch [Backward Position].

Touch [Menu] to return to the

SEP menu screen.

4 Touch the value in Position.

The numeric keypad appears.

Touch [1] and [0], and

touch [ENT].

Touch [Menu] to return to the

position setting screen.

5 10.00 is shown in Position.

Touch [Menu] to return to the

position setting screen.