5. Operation of CON Related Controllers

37

Timing at which the

completion signal turns ON

Positioning band

Ta

rg

et

po

si

tio

n

(5) Push

Select "Positioning operation" or "Push-motion operation."

The factory setting is 0.

0

: Normal positioning operation

Other than 0 : A current limiting value is indicated, meaning that this is a push-motion operation.

Caution: With PCON, ACON, SCON-C, SCON-CA, ERC2, ERC3, ROBONET and MSCON

controllers, the value entered in the "Push" field may be rounded to a multiple of the

controller's minimum resolution.

(When data is acquired from the controller)

(6) Positioning band

What this setting means is different between "Positioning operation " and "Push-motion operation."

"Positioning operation":

Define how far before the target position you want to turn the completion signal ON.

The factory setting is 0.1 mm.

Standard type

Increasing the value of positioning band quickens the start of the

next sequence operation, so the tact time can be reduced. Set an

optimal value by considering the balance of the entire system.

Note that on PCON-C/CG/CF, PCON-CA, ACON-C/CG, SCON-C, SCON-CA, ROBONET, ERC3 PIO Converter

and MSCON (Remote I/O mode) controllers of solenoid valve mode 1 or PCON-CY and ACON-CY controllers of

solenoid valve mode 1, set the band after which the completion signal turns ON.

PCON-C/CG/CF, PCON-CA, ACON-C/CG, SCON-C, SCON-CA, ROBONET, ERC3 PIO Converter

and MSCON (Remote I/O mode) in solenoid valve mode 2, PCON-CY, or ACON-CY in solenoid

valve mode 1

"Push-motion operation":

Define the maximum push distance from the target position in push-motion operation.

Set an appropriate positioning band by considering the mechanical variation of the work part, by making sure

positioning will not complete before the actuator contacts the work part.

(Note) For PCON-CA and ERC3, a smaller value than the minimum positioning band width cannot be set.

Position at which the load is contacted and completion of

push-motion operation is deemed complete and therefore

the completion signal turns ON

Load

Positioning band ON

(Maximum push distance)

Target position

Completion signal

Ta

rg

et

po

si

tio

n

Positioning band